5. Equipment
5-1 Eco Welding
The equipment is incorporated in Eco welding features that are aimed at performing
the lower noise, the lower fuel consumption and the lower gas emission than
conventional models.
When you turn the selector switch to Eco, you will be able to weld with Max.
5.0mmφwelding rod at the slow down speed.
<Caution>
z When welding is performed, do not turn the output selector switch, which causes
the burnout of the switch.
z Eco is designed for welding only. The 3-phase circuit breaker trips and
simultaneously the outputs of welding and generating would fall down and you will
not do anything when Eco is used for AC power supply.
5-2 Remote Control (Option)
Using the remote control box, the remote control to adjust the welding current
makes it possible.
Remote Control Box Connection
Remove “Eco” plate. (M4 Screw 2 pieces)
Insert the plug of the extension cable reel
into A side or B side receptacle
Insert the plug of the remote control box
into the receptacle of the extension cable
reel.
<Caution>
z Never connect the plug of the remote control box to the receptacle of the
extension cable reel when the reel is connected to 1-P receptacle.
z Never connect the other loads additionally than the remote control box.
z In the case the extension cable reel is installing the breaker, use the equipment to
have turned the breaker ON.
- 7 -