Shindaiwa DGW400DM-380A Welder User Manual


 
Check the fluid level. If the level is near or lower than LOWER level, add
distilled water until the fluid level reaches UPPER level.
Make sure that the battery cables are firmly secured to the posts. Tighten the
clamps if necessary.
<Caution>
z Check the hydrometer of the battery fluid. If it falls below 1.23, the battery
requires recharging. Please consult with our authorized distributor or our
engineering section.
Replacing battery
Remove the clamp and cable from negative (-) post in the battery.
(Remove always negative side first)
Remove the hold-down clamp from the battery.
Remove the clamp and cable from positive (+) post in the battery.
Remove the battery from the seat.
Reinstall a new battery in the reverse order.
(Install always the cable to the positive (+) post in the new battery first.)
<Caution>
z Use the following battery.
55B24L
- 18 -