9-2 Output Limitation
Please refer to the following table, because electric tools and home appliances
cannot be judged only by the rated output or the power consumption due to the
efficiency and character of the components.
Applicable Load (For reference purpose only)
Capacity (kW)
1-Phase
220-240V
1-Phase
380-415V
3-Phase
380-415V
Loads
Receptacle
total
Terminal
1 set
Terminal
3 set pairs
use
Terminal
Electric Bulb, Heater, etc.
3.0 9.0 12.0 -
Electric Tools, etc
(Series Motor),
1.5 4.5 6.0 -
Mercury Bulb
(High Power Factor Type)
1.2 3.6 4.8 -
Submersible Pump,
Compressor, etc
(Induction Motor)
1.2 3.6 4.8 6.0
Series Motor : Motor with brush
Induction Motor : Brushless Motor
The value described is OUTPUT for Induction Motor loads and POWER
CONSUMPTION for the other equipment.
<Caution>
z Be sure to use the frequency designated in the equipment incorporated in
mercury bulb or induction motor.
z The load incorporated in motor may require bigger power than the rated power
consumption. Therefore, consult with our authorized distributor or our
engineering section to clarify.
z When connecting to use 2 or more sets, start the load one by one, not to start
them simultaneously.
z When switching a Mercury bulb ON again, wait for 15 minutes (about) until it
cools down.