Shindaiwa DGW400DM-380A Welder User Manual


 
Stop the engine.
Connect a welding cable to a crimping terminal, a welding rod holder, and a
material holder.
Connect the welding cables to the output terminals per the table below.
Eco (Single) Single Dual
Welding Rod
φ2.0 – φ5.0
Welding Rod
φ2.6 – φ8.0
Welding Rod
φ2.0 – φ4.0
Welding Output Terminal A Welding Output Terminal A
Welding Output Terminal A
and
Welding Output Terminal B
Close the output terminal cover, after finishing connections, and fix the cover
with bolts.
<Caution>
z Be sure to crimp a crimping terminal to a cable and connect the cable to
welding output terminal. Otherwise, welding output terminals may burn out by
the heat caused by insufficient connections.
z Do not use a cable without a crimping terminal. If you use the cable, the
insulation is peeled off partly, to bind to an output terminal, the output terminal
may burn out by the heat caused by insufficient connections and also a bare
part of the cable may touch the bonnet to short-circuit.
8-4 Duty Cycle
Duty cycle means the weldable time ratio for 10 minutes. This equipment is the
rated duty cycle is 60%, namely, the weldable time is 6 minutes or less. Be sure to
take 4 minutes recess after 6 minutes welding.
<Caution>
z The equipment may be damaged due to overheat, if welding more than 6
minutes successively or short time recess after the welding.
- 22 -