Shindaiwa DGW400DM-380A Welder User Manual


 
Drain Water Every 200 hours
Unscrew the fuel drain plug.
Reinstall the drain plug, after draining water completely
<Caution>
z Change the packing, whenever changing oil.
z Packing Part No.: 6C090-58961 (Kubota)
(6) Changing Coolant/Water
Replace Every 2 years or 2000 hours
(Total Coolant/Water Capacity: 4.3 liter, including sub tank cap. 0.6 liter.)
1 Remove the top plate.
2 Remove the radiator cap.
3 Loosen the water drain plug.
4 After draining all the water, reinstall the water drain plug.
<Caution>
z Change the packing, whenever changing oil.
z Packing Part No.: 6C090-58961 (Kubota)
5 Replace all the water. In the sub tank.
6 Fill the coolant/water to the MAX level (to the upper edge of the inlet).
7 Reinstall the radiator cap.
8 Install the top plate back.
- 32 -