Shindaiwa DGW400DM-380A Welder User Manual


 
(1) Filling to the Reservoir Tank
Remove the sub tank cap.
Fill up the sub tank to the FULL level.
Install the cap back.
(2) Filling to the Radiator
Remove the top plate.
Remove the radiator cap.
Fill the radiator up to the top.
Install the cap back and tighten.
Reinstall the top plate.
<Caution>
z Use soft water, such as tap water.
z If the ambient temperature is near freezing, use Long Life Coolant (LLC) (30%
mixture LLC is filled when shipped from factory)
z Mixture ratio of the coolant should be 30%-45%, depending on the ambient
temperature.
z Replace LLC at every year or 2000 hours.
Mixture Ratio (for reference only)
Lowest Ambient
Temperature
-15 -20 -30
Mixture Ratio 30% 35% 45%
6-3 Checking Fuel
Caution : Fire
z Always wipe any drip of fuel. Do not use this equipment when any leak is found.
Repair the equipment before use.
Check for the fuel level in the tank. Add if necessary.
- 16 -