DELEte:SETUp, FACtory, *RCL, *RST, *SAV, SAVe:SETUp
RECAll:SETUp { FACtory | <NR1> | <file path> }
<file path>
<Space>
RECAll
:
FACtory
SETUp
<NR1>
FACtory selects the factory setup.
<NR1> is a value in the range from 1 to 10 and specifies a setup storage location.
Using an out-of-range value causes an execution error (222, “Data out of range”).
<file path> is the location in mass storage memory where the setup will be
recalled from.
<file path> is a quoted string that defines the file name and path. Input the file
path using the form <drive>/<dir>/<filename>. <drive> and one or more
<dir>s are optional. If you do not specify them, the TDS will read the file from
the default directory. <filename> stands for a filename of up to 8 characters
followed by a period (“.”) and any 3-character extension. Do not use wild card
characters.
The default directory refers to the name of a directory as returned by the
FILESystem:CWD command.
RECALL:SETUP FACTORY
recalls (and makes current) the front panel setup to its factory defaults.
RECALL:SETUP 1
recalls the front panel setup from setup1.
RECALL:SETUP TEK00000.SET"
recalls the front panel setup from the file TEK00000.SET in the default directory
and on the default drive.