Tektronix TDS644B Caulking Gun User Manual


 
Command Descriptions
TDS Family Oscilloscope Programmer Manual
2–305
ger:MAIn:PULse:RUNT:THReshold:HIGH commands. The crossing can be
either positive or negative as specified by TRIGger:MAIn:PULse: RUNT:PO-
Larity.
WIDth triggers when a pulse is found that has the specified polarity and is either
inside or outside the limits as specified by TRIGger:MAIn:PULse: WIDth:LOW-
Limit and TRIGger:MAIn:PULse:WIDth:HIGHLimit. The polarity is selected
using the TRIGger:MAIn:PULse:WIDth:POLarity command.
SLEWRate triggers when the slew rate of the source violates the specified
conditions (TDS 500C, 600B & 700C only).
TIMEOut triggers when the pulse train stops in the selected state for longer than
the specified time (TDS 500C, 600B, & 700C only).
TRIGGER:MAIN:PULSE:CLASS WIDTH
specifies a width pulse for the main trigger.
TRIGger:MAIn:PULse:GLItch? (Query Only)
Not on TDS 400A
Returns the current main glitch pulse trigger parameters.
Trigger
TRIGger:MAIn:PULse:GLItch?
TRIGger :
:
PULse
MAIn
GLItch
?
:
TRIGGER:MAIN:PULSE:GLITCH?
might return :TRIGGER:MAIN:PULSE:CLASS GLITCH;SOURCE CH1;
GLITCH:WIDTH 2.0E-9;FILTER ACCEPT;POLARITY POSITIVE.
TRIGger:MAIn:PULse:GLItch:FILTer
Not on TDS 400A
Controls glitch detection. This command is equivalent to selecting Filter in the
Trigger menu.
Trigger
Examples
Group
Syntax
Examples
Group