Workman 200 Ultra Sonic Boom System (Rev. C)Page 3.2 -- 23
Diagnostic Display
Outputs
Diagnostic Display
LED Operation
DIAG LAMP Diagnostic lamp is ON or FLASHING: LED ON or FLASHING
Diagnostic lamp is not ON or FLASHING: LED OFF
SONIC SENSOR TEC output exists to sonic sensors: LED ON
No TEC output to sonic sensors: LED OFF
RIGHT RAISE TEC output exists to energize relays to raise right boom: L ED ON
No TEC output to energize relays to raise right boom: LED OFF
RIGHT LOWER TEC output exists to energize relays to lower right boom: LED ON
No TEC output to energize relays to lower right boom: LED OFF
INDICATOR LAMP Sonic boom switch is in automatic position: LED ON
Sonic boom switch is in manual position: LED OFF
LEFT RAISE TEC output exists to energize relays to raise left boom: LED ON
No TEC output to energize relays to raise left boom: LED OFF
LEFT LOWER TEC output exists to energize relays to lower left boom: LED ON
No TEC output to energize relays to lower left boom: LED OFF
Ultra Sonic