50
Plast Coat 430
GB
malfunctIon possIble cause elImInatIon
Mortarsprayingmachinenot
running.
Green operating light lights up
Deliveryvolumecontrollerissetto„0“
Lance control cable not connected or
damaged
Switched to remote control operation
(Switch 6 Fig. 3 in Position “II”) but re-
mote control not connected
Increasedeliveryvolume
Check control cable
Connect a remote control or set switch (6 Fig. 3) to
Position “I”, in order to switch o operation with re-
mote control.
Mortarsprayingmachinenot
running.
Green operating light not does
not light up
Powersupplymissing. - Plug in the power plug.
- Check the power cable for damage and replace,
ifnecessary.
- Checkthepowersupply.
Mortarsprayingmachinenot
running.
Red indicator light lights up
Mortarsprayingmachinewasover-
loaded/overheated.
Close material tap and disconnect mains plug.
Switchthemortarsprayingmachineonagainafter
about 5 minutes.
Mortarsprayingmachinecan-
notbeswitchedon/oby
means of the remote control.
Remote control not on.
Remote control line not connected or
defect.
Set selector switch to “A” and set switch (Fig. 3, 6)
to position “II”, in order to activate remote control.
Connect remote control, check connections, check
remote control line for damage.
Mortarsprayingmachinecan-
not rotate the rotor
Rotor stuck in stator.
Pump was not lubricated with pump
sliding means.
Settheselectorswitchalternativelybrieyto“F”
(forwards) – “R” (reverse).
Contact Wagner customer service if the problem
cannot be resolved.
Mortarsprayingmachinebuilds
up pressure in the mortar hose.
However, coating material does
notarriveatthespraylance.
Coatingmaterial"plug"inthemortar
hose. Mortar hose not prerinsed with
cellulose paste.
Depressurize the mortar hose – set the selector
switch to “R” (reverse).
Pump the coating material back into the con-
tainer.
The mortar hose must be pres-
sureless.
Watch the manometer ––> 0 bar.
Wear safety goggles.
Decouple mortar hose and rinse with water hose.
When the plug has been removed, ll cellulose
paste in the mortar hose. Couple the mortar hose
back on.
10 ELIMINATING FAULTS
elImInatIng faults