Redball Electrical 565 Paint Sprayer User Manual


 
3-07
565 Trailer Sprayer - Operation Instructions
Section B
PTO Driven Centrifugal Pump: Make
sure your desired tractor speed turns the
PTO shaft at the correct speed. See the
pump manufacturer’s manual for further
operational information.
Fill Solution Tank:
Load the solution tank without using the trailer sprayer
pump via the following steps.
1. Close all valves.
2. Remove solution quick fill cap & connect load hose.
3. Open
solution quick fill valve and solution tank main
valve, located at the sump of the solution tank.
4. Open
valve on loading reservoir (i.e. nurse tank).
5. Start the remote transfer pump.
6. Run remote transfer pump until the desired amount
of solution is transferred into the trailer sprayer.
7. Close
valves on loading reservoir.
8. Close solution quick fill valve on trailer sprayer.
9. Remove load line & replace cap on trailer quick fill.
Small amounts of liquids will remain in the load hose.
Splashing of this liquid can cause a safety hazard to you and
to those in the vicinity of the trailer sprayer.
CAUTION
Overfilling will cause a failure of the tank lid causing splashing
of solution from the tank lid, which may be hazardous to you
and the environment.
CAUTION
5
Section B
IMPORTANT
Turn off a hydraulically driven centrifugal pump using the “float” posi-
tion of the tractor’s hydraulic valve. This allows the motor to stop
slowly helping to protect the motor and motor seals.
IMPORTANT
There are two basic rules to follow when operating a hydraulically
driven centrifugal pump:
1. Never run the pump in a “non-flooded” condition.
2. Always have the correct oil flow to the pump motor.
Always read and follow the pump manufacturer’s operational
instructions.
PTO Driven Centrifugal Pump
Outlet
Vent
Line
Suction
Line
Quick Fill Cap
Solution Quick
Fill Valve
Solution Tank
Main Valve