Redball Electrical 565 Paint Sprayer User Manual


 
3-07
Spraying
Spraying is accomplished via the following steps:
1. Close
all valves.
2. Open
the the solution tank main valve.
3. Setup control system. (Setup and operation of the
control system is covered in the manual provided by
the controller manufacturer.)
4. Power ON the liquid pump of the trailer sprayer.
5. Open desired spray boom section valves.
6. Perform spraying according to the control system
provided.
7. To stop spraying, close
all sprayboom section
valves.
8. Power OFF the liquid pump of the trailer sprayer.
Spraying with Agitation: Certain chemicals require
continuous agitation. If agitation is required during
spraying, open the agitation valve provided. If severe
foaming of your chemical occurs, check the chemical
label or your supplier to determine if agitation is required
or reduce the opening of the agitation valve to limit the
flow rate back to the solution tank. Reduce agitation if
adequate spray pressure cannot be maintained.
10
Section B
565 Trailer Sprayer - Operation Instructions
Section B
IMPORT
ANT
Turn off a hydraulically driven centrifugal pump using the “float” posi-
tion of the tractor’s hydraulic valve. This allows the motor to stop
slowly helping to protect the motor and motor seals.
Sprayboom Section Valves
Solution Tank
Main Valve
Handle
Solution Tank Main Valve
Agitation Valve