2 - 8 Ethernet RMON MultiProbe Module Installation and Operation Guide
Initializing the RMON MultiProbe Module
Once you complete module installation procedures and attach an RS-232
cable to the front panel, you can initialize the RMON MultiProbe Module
and display the configuration menus.
To initialize the RMON MultiProbe Module and display the configuration
menus:
1. Press the front panel Reset button. Pressing the Reset button
warm-starts the module. (Refer to Chapter 3, Configuring the
Module, for a description of warm and cold starts.)
When reset, the module completes diagnostics and initializes.
2. To display the RMON MultiProbe Module Main configuration menu,
hold down the X key on the terminal keyboard within 15 seconds of
powering up or resetting the module. If you do not hold down the X
key within 15 seconds, the RMON MultiProbe Module:
a. Begins monitoring the network
b. Reports any error messages if the module experiences an error
condition
3. If you miss the 15-second window, press the Reset button to
re-initialize the module.
4. When you hold down the X key, the following banner is displayed:
Tests interrupted!
Boot System Version x.xx for Ethernet RMON
MultiProbe, Rev x
Built on Thu April x, 17:36:58 EST 199x
Loading configuration system.
Entering configuration system. Please
wait.....