3 - 26 Ethernet RMON MultiProbe Module Installation and Operation Guide
Configuring the Module and Interfaces
Before the RMON MultiProbe Module can become operational, you must
configure the following parameters for the module and interfaces:
IP address (for each interface)
Subnet mask (for each interface)
Default gateway (for the module)
Assigning the Interface IP Address and Subnet Mask
You must assign a unique IP network address for each interface.
For example, if you do not bridge the three interfaces, you could assign IP
addresses for a subnetted class B network as shown in the following IP
address examples:
Note: In both of the IP address examples, each interface has a
subnet mask of 255.255.255.0.
Interface 1 - 151.104.36.7
Interface 2 - 151.104.37.8
Interface 3 - 151.104.38.9
For example, if you bridge the three interfaces, the network portion of the
IP addresses can be identical as shown in the following IP address
examples:
Interface 1 - 151.104.36.7
Interface 2 - 151.104.36.8
Interface 3 - 151.104.36.9