Apex Digital K1106 Grinder User Manual


 
23
Zone 10 Zone 11
Input Transmitter 1 Serial #: Input Transmitter 2 Serial #:
Option Location Default New Value Option Location Default New Value
Device 1152 005 Device 1164 005
Loop 1149 130 Loop 1161 130
Zone Type 0791 255 Zone Type 0807 255
Option 1 0787 080 Option 1 0803 080
Option 2 0788 000 Option 2 0804 000
Word 1 Word 3 Word 1 Word 3
Word 2 Word 4 Word 2 Word 4
Zone 12 Zone 13
Input Transmitter 3 Serial #: Input Transmitter 4 Serial #:
Option Location Default New Value Option Location Default New Value
Device 1176 005 Device 1188 005
Loop 1173 130 Loop 1185 130
Zone Type 0823 255 Zone Type 0839 255
Option 1 0819 080 Option 1 0835 080
Option 2 0820 000 Option 2 0836 000
Word 1 Word 3 Word 1 Word 3
Word 2 Word 4 Word 2 Word 4
Zone 14 Zone 15
Input Transmitter 5 Serial #: Input Transmitter 6 Serial #:
Option Location Default New Value Option Location Default New Value
Device 1200 005 Device 1212 005
Loop 1197 130 Loop 1209 130
Zone Type 0855 255 Zone Type 0871 255
Option 1 0851 080 Option 1 0867 080
Option 2 0852 000 Option 2 0868 000
Word 1 Word 3 Word 1 Word 3
Word 2 Word 4 Word 2 Word 4
Zone 16 Zone 17
Input Transmitter 7 Serial #: Input Transmitter 8 Serial #:
Option Location Default New Value Option Location Default New Value
Device 1224 005 Device 1236 005
Loop 1221 130 Loop 1233 130
Zone Type 0887 255 Zone Type 0903 255
Option 1 0883 080 Option 1 0899 080
Option 2 0884 000 Option 2 0900 000
Word 1 Word 3 Word 1 Word 3
Word 2 Word 4 Word 2 Word 4
Zones 18 - 23 continued on next page
Each of the 14 alarm point transmitters are defaulted as a supervised 5817 using loop 2. To adjust these settings,
enter the correct total from the options below in the Loop Location. When transmitters are being used that only have
one input, use loop 1.
Loop Options Value
Use Loop 1
...................................................................................................................
001
Use Loop 2
...................................................................................................................
002
Use Loop 3
...................................................................................................................
004
Enable 6 hour supervision
.............................................................................................
128
Default
.........................................................................................................................
130
Example: To program zone 12 as loop 3 on a supervised 5817, values 004 (Loop 3) and 128 (supervision) would be
added together (132) and entered into the Loop location for zone 12 (1173,132). To change zone 12 from a 5817 to
a 5816, location 1176 would be changed to 003 (from device listing).