54
code is entered or the two-way callback time expires. If neither code option is selected,
the system will be in listen-in mode when the phone is answered. Without the "0 exits to
keypad mode" options selected, the central station will not have access to keypad mode.
Two-way key functions: It is not recommended to alter the telephone digit assignments
for two-way voice, however, to conform to some central stations this process may be
necessary. To reassign the assignments, place a 001 in location 0161. Each of the two-
way functions are listed along with the digit assigned. By altering the location values,
each function can be reassigned to a new key digit. Take care when altering key
assignments not to program a single digit to have multiple functions. The system will
only expedite one function per telephone digit. Two-way voice is not permitted in a UL
installation.
Unattended Program Used in installations where the programming for the panel is entered into the PC
Download: software prior to the installation of the control panel. The software is left in auto answer
mode allowing the panel to call to PC, match numeric account numbers, and download
the programming file. Use location 9909 to set the panel account number and enter the
PC phone number in 9904 (shared with automatic EML upload) .
To initiate to automatic download sequence enter 9953.
Unbypass all Bypassed: This is a global option that allows all bypassed zones to become unbypassed each time
the system is disarmed. Bypass is not permitted in a UL installation.
User Code Options: The locations below each user number control the capabilities of each code. Add the
option values for each user and program the value in the appropriate location.
User Test Mode: A user Communicator test is integrated into the system to allow an end user to test the
system on a regular basis. Enter a valid user code followed by the "0" digit. The system
will speak "Enter User Test Mode." A User Communicator Test report is sent to the
central station. WHILE IN TEST MODE THE SYSTEM CEASES TO BE A SECURITY
SYSTEM. As each zone is tripped (including 24 hour zones) the system will speak the
zone description followed by "active." After 3 minutes (programmable) the panel will
automatically exit user test mode. To exit user test mode manually, enter a user code
followed by the "0" digit.
User Test Timeout: Controls the amount of time before the User Test Mode will automatically time out.
Voice Driver: With this option selected, output to the speakers will alternate between siren tones and
speech when there is a fire, burglary, emergency or panic activation. The system will say
"FIRE, FIRE, REMAIN CALM, LEAVE IMMEDIATELY", "INTRUSION DETECTED,
INTRUSION DETECTED", and "ALERT, ALERT". Not only will the type of activation be
spoken, but also the description of the zone that caused it.
Voice Only Wait Period: Amount of time the system will wait for a valid code during a secured two-way callback
or voice only session.
Wired/wireless Keypads: Allows use of the code on system keypads.
Zone Trouble Activation: This option applies only to supervised zones. With this option enabled, all trouble
conditions are treated as an activation when the system is armed.
Zone type assignment: Auxiliary: Auxiliary zones are non-burglary zones designed to provide an automation,
information, or service input to the system. This zone type does not activate an alarm
even when the system is armed. When monitor mode is active, the zone is programmed
to show open/close status at keypad and speak auxiliary zone type (System Option -
Group 5, option 001) is enabled, the system will speak the zone description or sound a
monitor beep when the zone input is activated. An auxiliary zone can be programmed
to alert the central station.