Apex Digital K1106 Grinder User Manual


 
51
Speak Phone Number: To confirm programmed phone numbers, Enter the appropriate 9000 location and the
number will be spoken. Special dialing feature codes will be heard as follows:
Dialing Feature Spoken As
Dial * Star
Dial # Pound
Wait for second dial tone Tone
3 second pause in dialing sequence Pause
Speak Pre-alarm: When this option is selected the system will repeat "ENTRY DETECTED" followed by a
zone description during pre-alarm in place of a low volume siren tone.
Speak Selected Word: This is used to play a specific word from the vocabulary.
Speak Software Revision: As dealers present ideas for new control panel options, the software is updated.
Although all software is labeled, this location verifies the software revision number.
Speak System Status: When this option is selected, the system speaks status through the inside speaker or over
the phone three seconds after pressing the first digit of a disarm code.
Speak Time and Date: With this option enabled, the system will speak time and date whenever a user requests
time (user code followed by 1).
Speak Zone Description: This routine prompts for a three digit zone number. The system speaks the description
associated with the selected zone. Zone 29 contains fixed words that are spoken when
there is an AC power loss, low battery and communicator failure.
Status on Local Phone: With this option selected the system will speak the system status instead of the
acceptance tone when you access the system from local phones.
Suppress Dialing During With this option set, the panel will only send new activation information to the central
Two-way Callback: station after a two-way callback call is complete. If this option is not set, a two-way
session can be terminated by the panel to allow additional information to be sent.
Two-way callback is not permitted in a UL installation.
Suppress Monitor: This option will prevent a zone from being enunciated when the system is in monitor
mode.
Suppress Open: This option will prevent the system from speaking the word "OPEN" at the end of a zone
description. This is useful when the object being monitored does not have an open or
closed state such as a driveway motion detector.
Suppress Siren: This option will cause a zone that normally produces an audible activation to produce a
silent alarm. The activation appears in system status, however no audible indication is
given.
3 Digit Disarm Code: This is a global option that converts all access codes to 3 digits instead of the traditional
4 digits.
Time Between Beeps: When using the extended monitor mode as an enunciator, you may wish to have audible
indication as well as visual. The extended monitor speech or beep will sound at intervals
determined by this time. Valid times are from 1 to 255 seconds. If a value of 000 is
programmed, NO speech or beep will be heard.
Time Frame for Bypass: The amount of time the activations must occur within before a zone is automatically
bypassed. Automatic bypassing of zones is not permitted in a UL installation.