Clear Keypad Status: Under very unusual circumstances, a keypad may not receive a transmission from the
control panel resulting in a status message not being cleared. This command clears all
status messages at the keypad.
Clear User Codes: This location will erase user codes 2 through 8.
Delay Before Dial: For both phone numbers, the system will wait a programmed time period (1 to 255
seconds) after activation before dialing the central station. If a value of 000 is
programmed, the communicator is disabled. If an alarm activation occurs and the
system is disarmed before the delay expires, the system will not communicate to the
central station. Valid delay values are 1-255 seconds.
Dial Alternate Number: If only one phone number is selected and the system is unable to communicate, the
system will try to contact the second number.
Dial Attempts: This option controls the maximum number of times the communicator will attempt to
call the central station. If the communicator is unable to connect with a central station,
the system will either stop dialing or begin dialing an alternate phone number. The
system can be programmed to show communicator trouble at the keypad if all dialing
attempts are unsuccessful. A communicator trouble condition will automatically clear
from the keypad the next time the system is armed.
Dial Phone Number 1: This option tells the control panel to always call phone number #1 if the corresponding
zone type is the cause of an activation.
Dial Phone Number 2: This option tells the control panel to always call phone number #2 if the corresponding
zone type is the cause of an activation.
Dialer Option: Each zone is individually programmed to report to the central station as well as each
zone type. If a zone is programmed to report to the central station and the zone type is
disabled or only programmed to report to the event memory log, the zone will NOT be
reported to the central station.
Direct Connect: Used with the PC software. Connect the modem to the panel's R and T terminals.
Activate the direct connect option in the PC software and with the control panel in
program mode, enter 9952.
Disable Force Arming: When this option is programmed, the system will not arm if zones are open unless the
system is armed from an Arm/Disarm zone input. This option must be enabled in a UL
installation.
Disappearing Activations: User codes 2-8 can be programmed as disappearing codes. A disappearing code
remains active for the number of times programmed in location 0129. When a code
becomes inactive, a user can reset the disappearing counter by changing the disarm
code.
Disarm Before Rearm: With this option selected, the system can only be armed from AWAY to HOME after
disarming and vice versa. This prevents an intruder from turning off interior protection if
they are able to circumvent perimeter protection.