Cabletron Systems NB30 Dust Collector User Manual


 
NB-30 Bridging
3-20 Bridge Spanning Tree
Protocol
Displays the Spanning Tree Algorithm Protocol type the NB-30 is currently using.
The choices are:
¥ 802.1
¥ DEC (DEC Lanbridge 100)
¥ None
The following four Þelds display values used for various Spanning Tree timers
that are set at the Root Bridge and this bridge. In Spanning Tree operations, the
value used for the tree is the one set at the Root Bridge (with the exception of
Hold Time, which is a Þxed value); but you can change the value for each bridge
on your network in the event that it becomes Root.
Hello Time
This parameter indicates, in seconds, the length of time the Root Bridge (or bridge
attempting to become the Root) waits before resending ConÞguration BPDUs.
The range for this Þeld is 1 to 10 seconds, with a default value of 2 seconds. The
Root Bridge sets the Hello Time.
Max Age
This parameter displays the bridgeÕs BPDU ageing timer. This controls the
maximum time a BPDU can be retained by the bridge before it is discarded.
During normal operation, each bridge in the network receives a new
ConÞguration BPDU before the timer expires. If the timer expires before a
ConÞguration BPDU is received, it indicates that the former Root is no longer
active. The remaining bridges begin Spanning Tree operation to select a new Root.
The current Root Bridge on the network sets the Max Age time. The range for this
Þeld is 6 to 40 seconds, with a default value of 20 seconds.
Forwarding Delay
This parameter displays the time period which elapses between states while the
bridge is moving to the Forwarding state. For example, while moving from a
Blocking to a Forwarding state, the port Þrst moves from Blocking to Listening to
BPDU activity on the network, remains there for the Forward Delay period, then
moves to the Learning State (and remains in it for the Forward Delay period), and
Þnally moves into a Forwarding state. This timer is set by the Root Bridge.
During a topology change, the Forward Delay is also used as the Filtering
Database Ageing Time (refer to the next section), which ensures that the Filtering
Database maintains current topology information.
Hold Time
This parameter displays the minimum time (1 second) that can elapse between
the transmission of ConÞguration BPDUs through a bridge port. The Hold Time
ensures that ConÞguration BPDUs are not transmitted too frequently through any
bridge port. Receiving a BPDU starts the Hold Timer. After the Hold Timer
expires, the port transmits its ConÞguration BPDU to send conÞguration
information to the Root. The Hold Time is a Þxed value, as speciÞed by the IEEE
802.1d speciÞcation.