DeWalt DeVILBISS Air Compressor User Manual


 
12- ENG
D23766
Extension Cords
Use extra air hose instead of an
extension cord to avoid voltage drop
and power loss to the motor, and to
prevent overheating.
If an extension cord must be used, be
sure it is:
a 3-wire extension cord that has
a 3-blade grounding plug, and a
3-slot receptacle that will accept
the plug on the product
in good condition
no longer than 50 feet
12 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases. 10 AWG and 8 AWG
may also be used. DO NOT USE
14 OR 16 AWG.)
INSTALLATION
GROUNDING INSTRUCTIONS
RISK OF
ELECTRICAL
SHOCK. In the event of a short
circuit, grounding reduces the risk
of shock by providing an escape
wire for the electric current. This
air compressor must be properly
grounded.
The portable air compressor is
equipped with a cord having a
grounding wire with an appropriate
grounding plug (see following
illustrations).
1. The cord set and plug with this
unit contains a grounding pin.
This plug MUST be used with a
grounded outlet.
HOW TO SET UP YOUR
UNIT
Location of the Air Compressor
Locate the air compressor in a
clean, dry, and well ventilated
area.
The air compressor should be
located at least 12" away from
the wall or other obstructions
that will interfere with the flow of
air.
The air filter and flywheel must
be kept clear of obstructions
which could reduce air flow to
the air compressor.
The air compressor requires fresh
air flow for proper cooling. DO
NOT ALLOW THE
COMPRESSOR TO GET WET.
Grounding Pin
Grounded
Outlets
Plug
IMPORTANT: The outlet being used
must be installed and grounded in
accordance with all local codes and
ordinances.
2. Make sure the outlet being used
has the same configuration as
the grounded plug. DO NOT
USE AN ADAPTER. See
illustration.
3. Inspect the plug and cord before
each use. Do not use if there are
signs of damage.
4. If these grounding instructions
are not completely understood,
or if in doubt as to whether the
compressor is properly
grounded, have the installation
checked by a qualified
electrician.
IMPROPER
GROUNDING CAN
RESULT IN ELECTRICAL SHOCK.
Do not modify the plug provided. If
it does not fit the available outlet, a
correct outlet should be installed
by a qualified electrician.
Repairs to the cord set or plug
MUST be made by a qualified
electrician.