Electrical Safety
Domestic Power Grounding
For safety, the power cords used on this product have a
three-wire, grounding-type power cord. Figures 2-1 and 2-
2 illustrate the appropriate electrical outlet to use with the
power cords included with 100-120 volt and 200-240 volt
systems respectively. This information applies to systems
shipped to North America or Japan.
International Power Grounding
The power cable normally provided for international use
is compatible with the power outlet used in many Conti-
nental European countries. Refer to Figure 2–3. However,
if your application requires another type of power cord,
check with your equipment supplier, and follow local reg-
ulations concerning proper wiring and grounding.
Figure 2–3 International 220/240V Grounding
Grounding Contacts
Typical Outlet
Provided Cable
Approved 2 pole, 3 wire grounding receptacle
HUBBELL No. HBL 5662 or equivalent
NEMA Configuration 6–15R or 6–20R
Figure 2–2 Example of 250 Volt,
Grounded, 3-Prong Receptacle
CAUTION
If you have a two-prong elec-
trical receptacle, we strongly
recommend that you replace
it with a properly grounded
three-prong type. Have a
qualied electrician replace
it following the National Elec-
tric Code and any local codes
and ordinances that apply.
See Figures 2–1 and 2–2.
CAUTION
If there is any question about
the grounding of your recep-
tacle, have it checked by
a qualified electrician. Do
not cut off the power cord
grounding prong, or alter
the plug in any way. If an
extension cord is needed,
use a three-wire cord that is
in good condition. The cord
should have an adequate
power rating to do the job
safely. It must be plugged
into a grounded receptacle.
Do not use a two-wire exten-
sion cord with this product.
Figure 2–1 Example of 125 Volt,
Grounded, 3-Prong Plug and Receptacle
Approved 2 pole, 3 wire grounding receptacle
HUBBELL No. HBL 5262 or equivalent
NEMA Configuration 5–15R or 5–20R