Dukane iQ Series Welding System User Manual


 
Page  58 
iQ Series, Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-577-01
Figure 9-2 Probes Outline Drawings and Dimensions
A
B
C
A
B
C
D
Standard single connector for
iQ generator
Soft grip handle
Standard cable
9 ft (3 m)
Air fitting for cooling
.25 in O.D. tubing
1.25 in (31.75 mm)
Diameter
Air fitting for cooling
.25 in O.D. tubing
Standard single connector for
iQ generator
Soft grip handle
1.25 in (32 mm)
Diameter
2.59 in
(66 mm)
1.20 in
(30 mm)
System
Model
Number
Generator
Model Number
Probe
Part
Number
Probe
Weight
lb (kg)
A
Diameter
in (mm)
B
Length
w/Strain Relief
in (mm)
C
Body
Length
in (mm)
D
Handle
Length
in (mm)
Probe
Cable
Length
HP 2.61-P 20HP060-1E
41PG20S
1.80 (.82)
1.90 (48)
8.75 (222) 5.10 (130) 5.38 (137)
9 ft (3 m)
HP 2.61-H 20HP060-1E
41HP20S
1.60 (.73) 10.00 (254) 5.02 (129)
HP 2.62-P 20HP060-2E
41PG20S
1.80 (.82) 8.75 (222) 5.10 (130) 5.38 (137)
HP 2.62-H 20HP060-2E
41HP20S
1.60 (.73) 10.00 (254) 5.02 (129)
HP 3.61-H 30HP060-1E
41HP30S
1.40 (.64) 9.00 (229) 5.10 (130)
HP 3.62-H 30HP060-2E
41HP30S
HP 4.61-P 40HP060-1E
41PG40S
1.65 (.75) 2.10 (53)
7.75 (197)
5.02 (129) 5.38 (137)
HP 4.61-H 40HP060-1E
41HP40S
1.35 (.61) 1.90 (48) 4.80 (122)
HP 4.62-P 40HP060-2E
41PG40S
1.65 (.75) 2.10 (53) 5.02 (129) 5.38 (137)
HP 4.62-H 40HP060-2E
41HP40S
1.35 (.61) 1.90 (48) 4.80 (122)