Dukane iQ Series Welding System User Manual


 
Page  24 
iQ Series, Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-577-01
Navigating Through the Modes
When the generator is rst powered up, the default
operating mode is Manual, and Manual Weld is shown
at the top of the display as shown in Figure 5-1.
Navigate to Time Mode
1. Follow the sequence shown in the gures to the right
to navigate from Manual mode to Time mode.
In Manual mode, press the TIME key (Figure 5-2).
2. The phrase, Enter Changes Mode, means when the
ENTER key is pressed, the mode will change. So
press the ENTER key, and the Weld by Time screen
seen in Figure 5-3 appears.
3. Set the time.
Use the and the keys to move the cursor
and to set the digits for the weld time you want.
4. Press the ENTER key to accept the time that has been
set (Figure 5-4).
Press the CANCEL key if you decide not to set the
time.
NOTE
Navigating to Manual Mode
Set Time or Energy (depending on mode) to
OFF, and press ENTER.
This will put you back in Manual mode.
Alternately:
Find an empty setup. Press SETUP.
Press ENTER.
A pop-up screen about defaults appears.
Select YES to load the default operating mode
which is Manual, and you can weld using the
Manual mode.
+ -
Manual Weld
Weld Time 0.000 S
Weld Energy 0 J
# 2
Figure 5-1 Manual Weld Mode
TIME key
Manual Weld
Weld By Time
OFF
Enter Changes Mode
ENTER key
Figure 5-2 Navigate to Time Mode
Weld by Time
Press Enter To Accept
Press Cancel To Abort
Weld By Time
OFF
S
Figure 5-3 Time Weld Mode - 1
Weld by Time
Press Enter To Accept
Press Cancel To Abort
Weld Time
0.500 S
Figure 5-4 Time Weld Mode - 2
ENTER key
Set the time.
Setup #1Empty
Load Defaults?
YES NO