7. Close solvent pump air valve (CB) and solvent shut-
off valve (AK) at mix manifold. Trigger spray gun to
relieve pressure.
8. Follow Pressure Relief Procedure, page 34.
9. Engage trigger lock.
10. Disassemble and clean spray tip with solvent by
hand. Reinstall on gun.
AK
TI1949a