Graco 312359J Paint Sprayer User Manual


 
Shutdown Entire System
312359J 39
Shutdown Entire System
Follow this procedure prior to servicing equipment or
shutdown.
1. Follow Flush Mixed Material, page 36. Use a metal
pail lid with a splash guard to avoid splashing.
2. Engage trigger lock, turn off air regulator, and close
main air shutoff valve. Remove spray tip.
3. For overnight shutdown:
•Follow Park Fluid Pump Rods on page 38.
Cap fluid outlets to keep solvent in the lines.
Fill pump A and B packing nuts with throat seal
liquid (TSL).
TI1953a
4)!
TI1949a
TI1948a