Graco 312359J Paint Sprayer User Manual


 
Appendix A
64 312359J
System Setup Screens
System Setup enables users to configure system set-
tings for fluid control and operator interaction. Refer to
the following table for details.
NOTE:
System settings must be enabled from the Enable Setup
screens before users can change or set configurations.
See Enable Setup Screens, page 66, for instructions.
Potlife/Hose Length
This screen enables users to set the potlife timer and
enter the hose inside diameter and length of each mixed
material hose specific to the system. The potlife time
displays in the upper right corner.
Set Potlife/Hose Length
To set the potlife timer and enter the mixed material
hose dimensions, press and to move through
each field, and press to make a field selectable.
Press and to select preferred units of mea-
surement for the potlife timer and length of each mixed
material hose. Press and to move to the
next digit in each field. Once the measurement unit in
the field is correct, press to save that measure-
ment.
When the fluid flow stops the displayed time counts
down in one minute intervals. The timer automatically
resets when the calculated mixed fluid volume is dis-
pensed.
Date/Time/Units
This screen enables users to set day, time, and units
that will be displayed on each screen.
Icon Function
Set number of minutes before mixed mate-
rial will set in hose. Resets after material
volume set by user is passed through hose.
Indicates total hose volume. Always dis-
played in cc units.
Set length of hose after mix manifold. Used
to indicated total hose volume.
Set calendar date and format.
Set time.
Set units of measurement desired for dis-
play, such as fluid and temperature.
Set sprayer number if using more than one
sprayer.
Set number of hours of recorded data to
record to USB data logs.
Set how often data will record to USB spray
logs.
Select resin pump size for A side.
Select hardener pump size for B side.