Enable Setup 2
(Shown with factory default settings.)
Maintenance Setup Screens
The maintenance setup 1 screen enables users to set
maintenance setpoint amounts for pumps and dosing
valves. The maintenance setup 2 screen enables users
to schedule the number of days between changing the
main incoming air filter before a reminder advisory will
sound.
The number displayed below each selectable field indi-
cates the amount of material dispensed, counting up to
the setpoint requiring maintenance.
Maintenance Setup 1
Maintenance Setup 2
Icon Function
Set amount of material moved through
pump that will result in a maintenance
warning.
Set amount of material moved through dos-
ing valve that will result in a maintenance
warning.
Set number of days between changing the
main incoming air filter before a reminder
advisory is issued.