Appendix C
312359J 79
Appendix C
Power Cord Guidelines
Use the guidelines listed in the following table to determine the power cord needed for your specific system.
◆ Wired by user if ordered. Cord size determined by user.
❄ Full load amperes with all components operating at maximum capabilities. Fuse requirements for various flow
rates and heater temperature settings may be less.
XM_A (00, 11, 13,
21, 23, 30-32)
XM_A (14-19,
24-29) XM_B (all) XM_C (all)
XM_D (00, 11, 13,
21, 23, 30-32)
XM_D (17, 19, 27,
29) XM_E (all)
Power Supply
wall wall wall; junction box wall alternator alternator alternator
Viscon HP Fluid
Heaters
N/A N/A 2 heaters 2 heaters N/A N/A 2 heaters
Configuration Options:
Controls
1 A, 120 Vac 1 A, 120/240 Vac 1 A, 240 Vac 1 A, 240 Vac N/A N/A N/A
Viscon HP (2)
N/A N/A 32 A at
240 Vac,
1 PH
32 A at
240 Vac,
1 PH
N/A N/A 32 A at 240 V,
1 PH (wired by
user with
explosion proof
methods)
Hopper
Immersion
Heaters (2)
N/A 13 A at 240 V,
1 PH
13 A at 240 V,
1 PH
13 A at 240 V,
1 PH
N/A N/A N/A
Viscon HP
with Heat
Circulation (1)
N/A
16 A at 240 V,
1 PH◆
or
15 A at 240 V,
1 PH◆
16 A at 240 V,
1 PH
or
15 A at 240 V,
1 PH
16 A at 240 V,
1 PH ◆
or
15 A at 240 V,
1 PH ◆
N/A 16 A at 240 V,
1 PH (wired by
user with
explosion proof
methods)
16 A at 240 V,
1 PH (wired by
user with
explosion proof
methods)
Electric Hose
Control (1)
N/A N/A N/A N/A
❄ Full Load Peak
Amperes at 240 V,
1 Phase
1 A 30 A 62 A 62 A 0 A
(air only)
16 A 48 A
Cord Specification AWG (mm
2
) at:
240 V, 1 PH
N/A
◆
4 (21.2)
2 wire + ground
◆
N/A N/A N/A
240 V, 3 PH
6 (13.3)
3 wire + ground
380 V, 3 PH
6 (13.3)
4 wire + ground
Table 3: Power Cord Guidelines