Grizzly G0451 Saw User Manual


 
G0451 14" Sliding Table Saw
-15-
Figure 8. Fuse installed at the 220V location.
3. At the voltage transformer, pull the fuse that
is in the “220” slot and push it into the “440”
slot (see Figure
8).
7. Rewire the motors as shown on the diagrams
that are placed on the inside of the motor wir-
ing covers.
4. Turn the dial (Figure 9) on the main motor
overload relay to 15A.
Main Motor
Overload
Relay Dial
Scoring
Motor Relay
Figure 9. Motor overload relays.
5. Remove the scoring motor overload relay and
replace it with the 440V overload relay. Set
the overload relay dial to 2A.
6. Open the motor cabinet door and remove the
motor wiring covers from the main motor and
the scoring motor (see Figure 10).
Scoring
Motor
Main
Motor
Figure 10. Motor locations.
Fuse