TYPe
Command :TGTctrl:TYPe<N> {{TOGgle|0} | {PULse|1} |
{SEQuence|2}}
The TYPe command sets the signal type for the specified signal. It does not
turn on the signal.
<N> An integer, 0 through 7, specifying signal.
Example OUTPUT XXX;":TGT:TYP2 SEQ"
Query :TGTctrl:TYPe<N>?
The TYPe query returns the current type of the signal. The default type is
toggle.
Returned Format [:TGTctrl:TYPe<N>] <type><NL>
<type> {0|1|2} where 0 indicates toggle, 1 indicates pulse, and 2 indicates
sequence.
TGTctrl Subsystem
TYPe