HP (Hewlett-Packard) A3311A Tool Storage User Manual


 
Troubleshooting & Diagnostics
Diagnostic Information
77
Troubleshooting
Table 18. Disk Module Additional Sense Code/Qualifier Codes
Byte
12-13
Description
00 00h No Additional Sense information
01 00h No index/sector signal
02 00h No seek complete
03 00h Peripheral device write fault
04 00h LUN not ready; cause not reportable
04 01h LUN not ready; becoming ready
04 02h LUN not ready; initializing command required
04 03h LUN not ready; manual intervention required
04 04h LUN not ready; format in progress
08 00h LUN communication failure
08 01h LUN communication time-out
08 02h LUN communication parity error
09 00h Track following error
09 04h Head select fault
0A 00h Error log overflow
0C 00h Write error
0C 01h Write error recovered with auto-reallocation
0C 02h Write error; auto-reallocation failed
10 00h ID CRC or ECC error
11 00h Unrecovered read error
11 01h Read retries exhausted
11 02h Error too long to correct
11 04h Unrecovered read error; auto reallocation failed
12 00h Address mark not found for ID field
12 01h Recovered data without ECC using previous sector ID
12 02h Recovered data with ECC using previous sector ID
14 00h Sector not found
14 01h Record not found
15 00h Random positioning error
15 01h Mechanical positioning error
15 02h Positioning error detected by read of medium
16 00h Data synchronization mark error
17 00h Recovered data with no error correction applied
17 01h Recovered data using retries