IBM EGX-400 Engraver User Manual


 
97
Chapter 5 - The Teaching Feature
5-7. List of Commands
21 SEL ORG
Function This selects an optional origin.
Value Optional origin (No. 1 through 100)
This changes the origin point for spindle positioning from the workpiece origin point to an optional origin. You can use
[OPTIONAL ORIGIN] at the [SETTING] submenu to store up to 99 optional origin locations (No. 2 through No. 100) in
memory. Selecting [No.1] restores the original workpiece origin point.
22 FINISH
Function This ends execution of a sequence.
Value None
A sequence must have this as its final command. It is normally sufficient for a sequence to have only one, at the end of the
sequence, but it poses no problem if a number of them appear throughout the sequence. If this command appears in the
middle of a sequence, execution ends when it is encountered.
23 DO NOTHING
Function This performs no operation.
Value None
This is used for inserting a dummy step and for similar purposes.
24 DELETE THIS STEP
This is not a command, and is not stored in memory. When you want to delete a single step, select this and press the
[ENTER/PAUSE] button. The displayed step is deleted.
25 INSERT NEW STEP
This is not a command, and is not stored in memory. When you want to insert a new step, select this and press the
[ENTER/PAUSE] button. The inserted step is a [DO NOTHING] operation.
1:
21 SEL ORG 2