44
Chapter 3 - Preparations
3-3. Cutter Installation Method 2 (No Nose Unit)
2. Menu Settings
5
Fully tighten the lock nut.
6
Use the menus to set [AUTO Z CONTROL] to OFF.
(1) Press several times to display the screen shown at right.
(2) Press
to move the blinking cursor to [OTHERS], then press .
(3) Press
several times to display the screen shown at right.
(4) Press to move the blinking cursor to [OFF], then press .
7
Use the menu to set [REVOLUTION] to ON.
(1) Press several times to display the screen shown at right.
(2) Press
to move the blinking cursor to [OTHERS], then press .
(3) Press to move the blinking cursor to [ON], then press .
8
Press several times to return to the top screen.
X 0 Y 0
Z 0 8000RPM
Be sure to set [AUTO Z CONTROL] to OFF.
I/O OTHERS
TEACHING SELF
AUTO Z CONTROL
ON <OFF>
REVOLUTION
<ON> OFF
I/O OTHERS
TEACHING SELF