93
Chapter 5 - The Teaching Feature
5-7. List of Commands
9 ARC
Function This moves the spindle head in an arc.
Value Relative location from the start point to the center of the circle (X and Y coordinates)
Value Angle from the arc start point to end point (-360 to 360 deg.)
Value Resolution (0 to 120 deg.)
Value Feed rate (0 to 50 mm/s)
This moves from the present location in an arc of the specified angle. Arc movement is possible only on the X and Y
plane.
Detail Screen 1
Specify the center of the circle. Specify relative coordinates from the present location, which is the start point. Note that
these are not coordinates referenced to the workpiece origin point. To go to Detail Screen 2, press the [ENTER/PAUSE]
button. To cancel and return, press the [MENU] button.
Detail Screen 2
Specify the angle from the start point to the end point. The direction of turning is determined by whether the value is
positive or negative. A positive value yields counterclockwise turning and a negative value yields clockwise turning. To
go to Detail Screen 3, press the [ENTER/PAUSE] button. To cancel and return, press the [MENU] button.
Detail Screen 3
Specify the resolution (smoothness) of the arc. Smaller values result in greater smoothness, but the apparent feed rate
becomes slower. Specifying [0] sets the machine's highest resolution. To go to Detail Screen 4, press the [ENTER/
PAUSE] button. To cancel and return, press the [MENU] button.
Detail Screen 4
Specify the feed rate. Specifying [0] sets a speed of 0.5 mm/s. To finish setting the value, press the [ENTER/PAUSE]
button. To cancel and return, press the [MENU] button.
1:
9 ARC
Basic Screen
Detail Screen 1
RELATIVE CENTER
X 500 Y 500
to cancel
Detail Screen 2
SET ANGLE
---> 90
Detail Screen 3
SET TOLERANCE
---> 5
Detail Screen 4
SET SPEED
---> 20
❶❶
to cancel
to cancel
to cancel
Center
Start point
End point
Angle
Y
X