IBM EGX-400 Engraver User Manual


 
131
Chapter 8 - Troubleshooting
8-3. Responding to an Error Message
20. Verify the Card
An attempt was made to access the memory card when no memory card was present.
This occurs when the memory card is removed during a menu operation that uses the memory card. When inserting or removing
a memory card, pause the machine and perform the operation while at the top screen.
After displaying this message, the machine automatically returns to the previous or original screen.
21. Data Error
A problem was found in a sequence imported from a memory card.
This occurs when a problem is encountered in the data format of a sequence using the teaching feature. A major cause of this is
corruption of the sequence due to a problem with the memory card or the like. Re-create the sequence.
After displaying this message, the machine automatically returns to the original screen.
22. Memory Write Error
A new sequence could not be created because the memory is full.
This occurs when the number of sequences that can be saved is exceeded (ten sequences for internal memory, or 512 for a
memory card). It also occurs when a memory card does not have enough free space. Take steps such as deleting unneeded
sequences, then redo the operation.
After displaying this message, the machine automatically returns to the original screen.
23. Card Access Error
The memory card was removed while being accessed.
The memory card was pulled out while it was being accessed. Turn off the machine, then redo the operation from the beginning.
When inserting or removing a memory card, pause the machine and perform the operation while at the top screen.
Data could not be written to the memory card.
This occurs when data could not be saved because the useful life of the memory card has ended or the memory card is damaged.
Try formatting the memory card. Alternatively, replace the memory card with a new one.
After displaying this message, the machine automatically returns to the original screen.
The memory card could not be accessed.
This occurs when reading and writing are completely impossible because of such reasons as a malfunction in the memory card.
Replace the memory card with a new one.
After displaying this message, the machine automatically returns to the original screen.