Lincoln Electric SVM105-B Welder User Manual


 
V300-PRO
OPERATION
B-4 B-4
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
METER POLARITY SWITCH
The wire feeder polarity switch is located at the rear of
the machine. The switch provides a work connection
for wire feeder voltmeters. Place the switch in the posi-
tion of the electrode polarity indicated by the decal.
The switch does not change the welding polarity.
AUXILIARY POWER
A 24 VAC @ 1 amp supply is included for use with the
LN-25 wire feeder (24 volts needed for K431 and
K432 options). This supply is protected by a self-
resetting current limiter.
A 42 VAC @ 5.5 amp supply is included for use with
other wire feeders. This supply is protected by a 6
amp breaker located on the rear of the machine.
A110/115 VAC @ 2 amp supply is included for use
with the LN-7 or LN-9 GMA wire feeders. This supply
is protected by a 2.5 amp breaker located on the rear
of the machine. It is NOT
available on IEC units.
All three supplies are not to be loaded simultaneous-
ly
-
+
OUTPUT TERMINALS
LINCOLN