Lincoln Electric SVM105-B Welder User Manual


 
V300-PRO
TROUBLESHOOTING & REPAIR
F-27 F-27
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
SWITCH BOARD TEST (CONT.)
Apply Positive Apply Negative
Test Probe to Test Probe to
Terminal Terminal Test Result Conclusion Repair Action Next Procedure Notes
1/8 12 Greater than OK None Continue
1K ohm
Less than Shorted Replace both Snubber Test
100 ohms Switch Boards
12 1/8 Less than OK None Continue
100 ohms
Greater than Open Replace both Snubber Test
1K ohm Switch Boards
9 4/5 Greater than OK None Continue
1K ohm
Less than Shorted Replace both Snubber Test
100 ohms Switch Boards
4/5 9 Less than OK None Continue
100 ohms
Greater than Open Replace both Snubber Test
1K ohm Switch Boards
1/8 9 Less than OK None Continue
100 ohms
Greater than Open Replace both Snubber Test
1K ohm Switch Boards
9 1/8 Greater than OK None Continue
1K ohm
Less than Shorted Replace both Snubber Test
100 ohms Switch Boards
12 4/5 Less than OK None Continue
100 ohms
Greater than Open Replace both Snubber Test
1K ohm Switch Boards
4/5 12 Greater than OK None Continue
1K ohm
Less than Shorted Replace both Snubber Test
100 ohms Switch Boards
NOTE: K ohm = ohm reading multiplied by 1000.
NOTE: Always make sure that Switch Boards are changed in matched pairs. Never mix an old style (different
part number) Switch Board with a newer style.
TABLE F.2
SWITCH BOARD RESISTANCE CHECKS