Lincoln Electric SVM107-B Welder User Manual


 
OPERATION
B-4 B-4
RANGER 8
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Starting/Shutdown Instructions
Starting the Engine
Be sure all Pre-Operation Maintenance has been per-
formed. Also, read the Engine Owner’s Manual.
Remove all loads connected to the AC power recepta-
cles. To start the engine, set the “Idler Control” switch
in the Automatic ( / ) position.
Use the choke control as follows:
Onan Engine - If the engine is cold, pull the choke
control out. Do not use the choke if the engine is warm
or hot.
Kohler Engine - Always pull the choke control out
when starting the engine; cold, warm or hot. Place the
“Engine” switch in the “ON” position.
Honda Engine - Always pull the choke control out
when starting the engine; cold. Place the “Engine”
switch in the “ON” position.
Push the “START” button and crank the engine until it
starts. Release the button as soon as the engine
starts. Do not push the “START” button while the
engine is running because this will cause damage to
the ring gear and/or starter motor. After the engine has
started, slowly return the choke control to the full “in”
position (choke open).
After running at high engine speed for 10-14 seconds,
the engine will go to low idle.
Allow the engine to warm up by letting it run at low idle
for a few minutes.
Stopping the Engine
Remove all welding and auxiliary power loads and
allow engine to run at low idle speed for a few minutes
to cool the engine.
Stop the engine by placing the “Engine” switch in the
“OFF” position.
A fuel shut off valve is not required on the Ranger 8
because the fuel tank is mounted below the engine.
Break-in Period
It is normal for any engine to use a greater amount of
oil until the break-in is accomplished. Check the oil
level twice a day during the break-in period (approxi-
mately 50 running hours)).
IMPORTANT: IN ORDER TO ACCOMPLISH THIS
BREAK-IN, THE UNIT SHOULD BE
SUBJECTED TO MODERATE
LOADS, WITHIN THE RATING OF
THE MACHINE. AVOID LONG IDLE
RUNNING PERIODS. REMOVE
LOADS AND ALLOW ENGINE TO
COOL BEFORE SHUTDOWN.
The engine manufacturer’s recommendation for the
running time until the first oil change is as follows:
The oil filter is to be changed at the second oil change.
Refer to the Engine Owner’s Manual for more informa-
tion.
• Do not touch electrically live parts
of electrode with skin or wet
clothing.
• Keep flammable material away.
• Insulate yourself from work and
ground. Wear eye, ear, and body
protection.
• Keep your head out of the fumes.
• Use ventilation or exhaust to
remove fumes from breathing
zone.
WARNING
Honda
GX620KI
First Month
or 20 HRS
Kohler
CH20S
5 HRS
Onan
P220
25 HRS