Lincoln Electric SVM134-A Welder User Manual


 
The Lincoln Electric LN-25 wire feeder is recommend-
ed for wire feed welding with the Classic I.
CONNECTION OF THE LN-25 TO THE
CLASSIC I “ACROSS THE ARC” WITH
WIRE FEED MODULE (SEE FIGURE C.1.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-25 to the
“+” terminal of the welder. Connect the work cable
to the “CV–” terminal of the welder.
NOTE: Welding cable must be sized for current
and duty cycle of application.
NOTE: Figure C.1 shows the electrode connect-
ed for positive polarity. To change polari-
ty, shut the welder off and reverse the
electrode and work cables at the Classic I
output terminals. Reverse the LN-25
polarity switch.
3. Connect the K444-2 remote control cable to the 14
pin amphenol on the Wire Feed Module.
4. Attach the single lead from the LN-25 control box
to the work using the spring clip on the end of the
lead. This is only a control lead — it carries no
welding current.
5. Place the IDLER switch in the “HIGH” position.
6. Adjust wire feed speed and voltage at the LN-25.
ACCESSORIES
C-3 C-3
CLASSIC I
FIGURE C.1
CLASSIC I/LN-25 ACROSS THE ARC CONNECTION DIAGRAM
TO
WORK
14 PIN
AMPHENOL
WORK CLIP
LEAD TOWORK
LN-25 WIREFEEDER
WITH K444-2REMOTE
VOLTAGE CONTROL OPTION
ELECTRODE CABLE
CV-
+
CONNECTION OF LINCOLN
ELECTRIC WIRE FEEDERS
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC