B-5
OPERATION
B-5
LN-10
Robotics Mode Selection
The LN-10 control is set up for Robotics Mode by set-
ting the S2 DIP Switch 4 (Labeled “R”). For Robotics
Interface Mode to operate, a K1561-1 Robotics
Interface Module must be installed.
S2 switch 4 ON = Robotics mode ON
S2 switch 4 OFF = Robotics mode OFF (As shipped)
Maximum Limits Setting Mode Selection
The LN-10 control is set up for allowing a maximum
weld WFS and arc voltage setting for each procedure
by setting S2 DIP Switch 5 (Labeled “+”)
S2 switch 5 ON = Max. Limits Setting mode ON
When Maximum Limits Setting mode is selected, all keys
except the procedure key are disabled. Welding is not
allowed while in this mode. The mode is used for maxi-
mum limits setup only. See “Limits Setting Mode” in
this section for the correct procedure for setting the WFS
and voltage limits.
S2 switch 5 OFF = Maximum Limits Setting mode
OFF (As shipped)
Minimum Limits Setting Mode Selection
The LN-10 control is set up for allowing a minimum weld
WFS and arc voltage setting for each procedure by set-
ting S2 DIP Switch 6 (Labeled “-”).
S2 switch 6 ON - Minimum Limits Setting mode ON
When Minimum Limits Setting mode is selected, all keys
except the procedure key are disabled. Welding is not
allowed while in this mode. The mode is used for mini-
mum limits setup only. See “Limits Setting Mode” in
this section for the correct procedure for setting the WFS
and voltage limits.
S2 switch 6 OFF = Minimum Limits Setting mode OFF
(As shipped)
M 4 S R + -
S2
ON
S2
12345678
M 4 S R + -
S2
ON
S2
12345678
M 4 S R + -
S2
ON
S2
12345678
M 4 S R + -
S2
ON
S2
12345678
M 4 S R + -
S2
ON
S2
12345678
M 4 S R + -
S2
ON
S2
12345678
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC