Lincoln Electric SVM170-A Welding System User Manual


 
F-28
TROUBLESHOOTING AND REPAIR
F-28
POWER MIG 255C
3. Locate plug J1 on the control PC board.
See Figure F.9.
4. Locate the following leads on plug J1:
5. Connect the main power to the
machine.
TEST PROCEDURE
NOTE: POLARITY MUST BE OBSERVED
FOR THESE TESTS.
Test for Correct Wire Drive Motor Armature
Voltage
1. Disconnect main input power to the
machine.
2. Open the side panels and remove the
tool tray using a 5/16 in. nutdriver.
FIGURE F.9 — PLUG J1 LOCATION ON CONTROL PC BOARD.
J6
J5
J3
J8
J1
J4
J2
#555
(6J1)
W
(2J1)
#206B
(1J1)
#515B
(5J1)
B
(4J1)
WIRE DRIVE MOTOR AND TACHOMETER FEEDBACK TEST (continued)
PLUG
LOCATION
4J1
2J1
LEAD
B
W
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
J6
J5
J3
J8
J1
J4
J2
#555
(6J1)
W
(2J1)
#206B
(1J1)
#515B
(5J1)
B
(4J1)