Lincoln Electric SVM170-A Welding System User Manual


 
F-35
TROUBLESHOOTING AND REPAIR
POWER MIG 255C
F-35
0 VOLTS
2.00 V 5 ms
TYPICAL SCR GATE VOLTAGE WAVEFORM
This is a typical SCR gate pulse voltage
waveform. The machine was in an open
circuit condition (no load) and operating
properly. Note that each vertical division
represents 2 volts and each horizontal
division represents 5 milliseconds in time.
NOTE: Scope probes connected at Plug J6
on the control board. The (+) probe to lead
G2, and the (-) probe to lead 204.
Volts/Div . . . . . . . . . . . . . . . . . . 2.0 V/Div
Horizontal Sweep . . . . . . . . . . 5 ms/Div
Coupling . . . . . . . . . . . . . . . . . . . . . . DC
Trigger . . . . . . . . . . . . . . . . . . . . Internal
SCOPE SETTINGS
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC