Lincoln Electric SVM170-A Welding System User Manual


 
F-32
TROUBLESHOOTING AND REPAIR
POWER MIG 255C
F-32
0 VOLTS
20.0 V 5 ms
MACHINE LOADED TO 250 AMPS AT 26 VDC
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
This is a typical DC output voltage waveform
generated from a properly operating
machine. Note that each vertical division
represents 20 volts and that each horizontal
division represents 5 milliseconds in time.
The machine was loaded with a resistance
grid bank.
NOTE: Scope probes connected at machine
output terminals: (+) probe to electrode, (-)
probe to work.
Volts/Div . . . . . . . . . . . . . . . . . . 20 V/Div
Horizontal Sweep . . . . . . . . . . 5 ms/Div
Coupling . . . . . . . . . . . . . . . . . . . . . . DC
Trigger . . . . . . . . . . . . . . . . . . . . Internal
SCOPE SETTINGS
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC