Lincoln Electric SVM176-A Welder User Manual


 
THEORY OF OPERATION
E-4E-4
LN-23P
OPTIONAL CIRCUITS
K350 / K350-1ADAPTER KITS
The K350 Adapter kits are used to interface one or
two LN-23P feeders to a Lincoln CV power source.
Figure E.4 shows a typical two feeder connection
using a K350-1. If only one feeder is used it must
be connected to the “Feeder A” terminal strip.
NOTE: Many of the newer power sources allow a
single feeder to be connected without using
an adapter kit. See the connection diagrams
in Section G.
In a two feeder system, both guns will be ʻHOTʼ
when either gun is triggered
In a two feeder system, triggering the second gun
while one is welding may cause the feeder in use
to shut down.
FIGURE E.4 – OPTIONAL CIRCUITS.
NOTE: Unshaded areas of block logic diagrams are the subject of discussion.