Miller Electric Big 40 WG Welding System User Manual


 
OM-4405 Page 21
4-11. Connecting To Remote 14 Receptacle RC14 On CC/CV Models
Socket* Socket Information
24 VOLTS AC
A 24 volts ac. Protected by circuit
breaker CB5.
24 VOLTS AC
B Contact closure to A completes
24 volt ac contactor control
circuit.
New! LDR-14 long
distance remote
(includes 120 V
receptacle)
C Output to remote control:+10
volts dc in MIG or Stick mode;
0 to +10 volts dc in TIG mode.
receptacle)
REMOTE
OUTPUT
D Remote control circuit common.
OR
CONTROL
E DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
802 729
GND
K Chassis common.
NEUTRAL G Circuit common for 24 volt ac
circuit.
*The remaining sockets are not used.