Miller Electric Big 40 WG Welding System User Manual


 
OM-4405 Page 34
8-2. Routine Maintenance
Follow the storage procedure in the engine owners manual if the unit will not be used for an
extended period.
Note
Recycle engine
fluids.
Y Stop engine before maintaining.
. See also Engine Manual and Mainte-
nance Label. Service unit more often if
used in severe conditions.
* To be done by Factory Authorized
Service Agent.
8 h
Check Fluid
Levels. See
Section 4-7.
Wipe
Up
Spills.
OIL
Full
Coolant
Full
50 h
Clean Air Filter.
See Section 8-4.
Clean And
Tighten
Weld
Terminals.
1/2 in.
(13 mm)
Check Belt
Tension.
100 h
Change Oil. See
Section 8-8.
Change Oil
Filter. See
Section 8-8.
Clean And
Tighten
Battery
Connections.
Replace fuel
filter. See
Section 8-8.
Check air cleaner hoses
for cracks and loose
clamps.
250 h
Check And
Clean Spark
Arrestor. See
Section 8-3.
Check
Spark
Plugs.
Replace
Unreadable
Labels.