Toshiba ste 58761 Welding System User Manual


 
STE 58761
2-4
2.2.2 Hot Starting
!
Caution
If an abnormality has generated or the POWER LED lamp on the control panel remains off after
the main power switch of the equipment was turned on, turn off the main power immediately
and confirm the wiring. Otherwise, you will be struck by an electric shock or a fire will break
out. When hot starting has been done, the controller enters a program reset status.
(1) Function
Starts up the controller with files contained in the RAM drive.
(2) Input format
None
(3) Comments
The following subscription files must be in the RAM drive:
CONSTRUC. SYS EXTRNSEL. SYS *
ALARM. MES * SCOL . LIB *
SYSTEM. PAR AUTOSTR. BAT *
USER. PAR
Files marked by an asterisk are not absolutely necessary to run the system.
However, you will get an error should you try to execute a function dependent
on a missing file.
For more information on these files, see the Start-up Manual.