Toshiba ste 58761 Welding System User Manual


 
STE 58761
4-2
(4) Procedure
(a) Step 1: Select the Manual Mode
Turn the master mode switch on the control panel to "MANU".
(b) Step 2: Select the Auxiliary Signal Operation Mode
Push the "Aux. Signal" key on the teach pendant. The Auxiliary Signal Operation
Mode menu should then appear.
Auxiliary signal operation mode
[210] [212] [214]
[208] [209] [211] [213]
Aux 1 Aux 2 Aux 3 Aux 4 Aux 5 Aux 6
The numbers on the screen correspond to the output signal ports. Auxiliary
signals having two output signal ports are set for double solenoids, and those
having one output signal port are set for single solenoids. Those having no
output signal ports are not set for anything.
Ports that are highlighted in the display are on and ports that are not are off.
(c) Step 3: Turn ports on and off as appropriate
Each time you push a function key corresponding to a port, the status of the
solenoid will change from on to off or from off to on. For double solenoids, the
status of the two ports will be transposed.