York YR Air Compressor User Manual


 
10
YORK INTERNATIONAL
FORM 160.81-EG1
OptiView Control Center (continued)
The USER screen allows definition of the language for
the chiller to display and defines the unit of measure.
Programmable:
System Language
English/Metric Units
The COMMS screen allows the user to define commu-
nications parameters.
Programmable:
Chiller ID
COM 2 Baud Rate
COM 2 Data Bit(s)
COM 2 Parity Bit(s)
COM 2 Stop Bit(s)
Printer Baud Rate
Printer Data Bit(s)
Printer Parity Bit(s)
Printer Stop Bit(s)
The PRINTER screen permits the user to define com-
munications Parameters for the Printer.
Display Only
Time Remaining Until Next Print
Programmable
Log Start Time
Output Interval
Automatic Printer Logging (Enabled/Disabled)
Print Type
Print Report
Print All Histories
The SALES ORDER screen allows definition of the or-
der parameters. Note: This information is loaded at the
factory or by the installation service technician.
Display Only
Model Number
Panel Serial Number
Chiller Serial Number
YORK Order Number
System Information
Condenser and Evaporator Design Load Information
Nameplate Information
The OPERATIONS screen permits definition of param-
eters pertaining to operation of the chiller. What is de-
fined is whether the control of the chiller will be Local,
Digital Remote, Analog Remote, Modem Remote or ISN
Remote.
Programmable
Control Source
The HISTORY screen allows the user to browse through
the last ten faults; either safety or cycling shutdowns
with the conditions, while the chiller is running or
stopped. The faults are color coded for ease in deter-
mining the severity at a glance, recording the date, time
and description. (See Display Messages for Color Code
meanings.)
Display Only
Last Normal Shutdown
Last Fault While Running
Last Ten Faults
Programmable:
Print History
Print All Histories
By pressing the VIEW DETAILS key you will move to
the HISTORY DETAILS screen. From these screens
you are able to see an on-screen printout of all the sys-
tem parameters at the time of the selected shutdown.
Display Only:
History Printout
Programmable:
Page Up
Page Down
Print History
Also under the HISTORY screen is the TRENDING
screen, accessible by the key marked the same. On
this screen, up to six operator-selected parameters, se-
lected from a list of over 140, can be plotted in an X/Y
graph format. The graph can be customized to record
points once every second up to once every hour. There
are two types of charts that can be created: single
screen, or continuous screen. The single screen col-
lects data for one screen width (450 data points across
the X-axis), then stops. The continuous screen keeps