A SERVICE OF

logo

184
Communication operation and setting
[Fault data]
Refer to page 237 for details of fault description
[Run command]
∗1
The signal is the initial setting. The description changes depending on the setting of
Pr. 180 to Pr. 182 (input terminal function selection) (page 100)
.
∗2 When Pr. 551 = "2" (PU mode control source is PU connector), only forward rotation and reverse rotation can be used.
Item
Instruction
Code
Bit
Length
Description Example
Run
command
HFA 8 bits
b0: terminal 4 input selection (Fixed)
∗2
b1: forward rotation command (Fixed)
b2: reverse rotation command (Fixed)
b3: RL (low-speed operation command
∗1 (Variable)) ∗2
b4: RM (middle-speed operation
command ∗1 (Variable)) ∗2
b5: RH (high-speed operation
command ∗1 (Variable)) ∗2
b6: second function selection (Fixed)
∗2
b7: output stop (Fixed) ∗2
Run
command
(expansion)
HF9 16 bits
b0: terminal 4 input selection (Fixed)
∗2
b1: forward rotation command (Fixed)
b2: reverse rotation command (Fixed)
b3: RL (low-speed operation command
∗1 (Variable)) ∗2
b4: RM (middle-speed operation
command ∗1 (Variable)) ∗2
b5: RH (high-speed operation
command ∗1 (Variable)) ∗2
b6: second function selection (Fixed)
∗2
b7: output stop (Fixed) ∗2
b8 to b15: —
For read data H3010
(Previous fault ...... THT)
(Latest fault...OC1)
0
1
0
1
0000 0 1 0000
00
b15 b8b7 b0
Latest fault
(H10)
Previous fault
(H30)
Fault record display example (instruction code H74)
Data Definition
H00
No fault
present
H10 E.OC1
H11 E.OC2
H12 E.OC3
H20 E.OV1
H21 E.OV2
H22 E.OV3
H30 E.THT
H31 E.THM
H40 E.FIN
H52 E.ILF
H60 E.OLT
H61 E.SOT
H70 E.BE
H80 E.GF
H81 E.LF
H90 E.OHT
H91 E.PTC
HB0 E.PE
Data Definition
HB1 E.PUE
HB2 E.RET
HC0 E.CPU
HC4 E.CDO
HC5 E.IOH
HC7 E.AIE
HC9 E.SAF
HD0 E.OS
HE6 E.PID
HF5 E.5
Data Definition
00000010
b7 b0
[Example 1] H02... Forward rotation
[Example 2] H00... Stop
00000000
b7 b0
00000010
b0
[Example 1] H0002... Forward rotation
00000000
b15
00100000
b0
00000000
b15
[Example 2] H0020... Low speed operation
(When Pr. 182 RH terminal function selection
is set to "0")